| Name |
Description |
Current Value |
Code |
Status |
Enabled |
Extension |
Error Level [f] |
| AAR |
Automatic accessory recognition |
|
|
|
X |
|
|
| ABP |
Absolute peak position |
1000071 |
1000071 |
|
X |
|
|
| ACS |
Select Accessory |
0 |
0 |
|
X |
|
Enabled |
Call |
| 0xFE80 (External Accessory) |
|
|
Enabled |
Connected |
| ENTRY_NUM_ADDR=0xFE80 |
|
|
| 0xFEA0 (Front Accessory) |
X |
|
Enabled |
Connected |
| ENTRY_NUM_ADDR=0xFEA0 |
X |
X |
|
|
|
| ADC |
Get Analog Input |
|
0, 0 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=AdiAnalogIn |
|
|
|
|
| ADM |
Scanner adjustment mode |
Reinit |
0 |
|
X |
|
Enabled |
| 0 (Reinit) |
X |
| 1 (Fast Adjust Mode) |
X |
| 2 (Stop) |
X |
| 3 (Slow Adjust Mode) |
X |
|
|
| AQM |
Aquisition Mode |
Double Sided,Forward-Backward |
DD |
|
X |
|
Enabled |
| DD (Double Sided,Forward-Backward) |
X |
|
W |
| BMS |
Set beamsplitter |
KBr |
1 |
|
X |
|
Enabled |
Call |
| 1 (KBr) |
X |
|
Enabled |
Connected |
| DA_MOT=0xFE20 |
X |
X |
| ENTRY_NUM_ADDR=0xFE20 |
X |
X |
|
|
|
| BRK |
Break |
0 |
0 |
|
X |
|
Enabled |
| 1 (Abort measurement) |
X |
| 2 (Stop measurement) |
X |
| 4 (Skip current "Waiting for Delay") |
X |
| 8 (Skip current "Waiting for Trigger") |
X |
| 16 (Skip current "Waiting for RDY") |
X |
| 32 (Stop repeated measurement) |
X |
|
|
| CALIBRATE_SRC_DIG_POTI |
|
0 |
0 |
|
X |
|
|
| CAN |
CAN Bus |
|
|
|
X |
|
|
| CCT |
Correct crystal temperature |
0.000000 |
0.000000 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=TemperatureController |
|
|
|
|
| CHD |
Temperature control derivative gain |
0.000000 |
0.000000 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=TemperatureController |
|
|
|
|
| CHI |
Temperature control integral gain |
0.000000 |
0.000000 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=TemperatureController |
|
|
|
|
| CHN |
Measurement channel |
Sample Compartment |
1 |
|
X |
|
Enabled |
Call |
| 1 (Sample Compartment) |
X |
|
Enabled |
Connected |
| G_MOT=0xFF20, 0 |
X |
X |
|
| 2 (Background) |
|
|
Enabled |
Connected |
| G_MOT=0xFF20, 1 |
|
|
|
|
| CHP |
Temperature control proportional gain |
0.000000 |
0.000000 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=TemperatureController |
|
|
|
|
| CMA |
Correlation mask |
0 |
0 |
|
X |
|
Enabled |
Call |
| 4 (ADC FS) |
X |
|
| 8 (Vel) |
X |
|
| 32 (IFG Length Diff) |
X |
|
| 2048 (Unstable Sample Temperature) |
|
|
Enabled |
Connected |
| DT_MOT=TemperatureController |
|
|
| 8192 (Detector Not Ready) |
X |
|
Enabled |
Connected |
| DT_MOT=Detector |
X |
X |
|
|
|
| CMD_STACK |
Command restore stack |
|
|
|
X |
|
|
| CNM |
Operator name |
|
|
|
X |
|
|
| COR |
Correlation on/off |
Off |
0 |
|
X |
|
Enabled |
| 0 (Off) |
X |
| 1 (On) |
X |
|
|
| CPD |
Derivative scanner control parameter |
2000 |
2000 |
|
X |
|
|
| CPI |
Integral scanner control parameter |
500 |
500 |
|
X |
|
|
| CPP |
Proportional scanner control parameter |
5000 |
5000 |
|
X |
|
|
| CRM |
Correlation Reject Mask |
-1 |
-1 |
|
X |
|
Enabled |
| 14336 (Unstable Sample Temperature Or Vial Not Inserted Or Detector Not Ready) |
X |
| 2048 (Unstable Sample Temperature) |
X |
| 4096 (Vial Not Inserted) |
X |
| 8192 (Detector Not Ready) |
X |
|
|
| DAC |
Set Analog Output |
|
0, 0, 0 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=AdiAnalogOut |
|
|
|
|
| DAT_MOT |
Dummy command to enable/disable commands using units with given id and type |
0 |
0 |
|
|
|
|
| DA_MOT |
Unit ID |
0 |
0 |
|
|
|
|
| DEL |
Delay before measurement |
0 |
0 |
|
X |
|
|
| DFO |
Data format |
DFO_RAW_IGRAM |
1 |
|
X |
|
Enabled |
| 1 (DFO_RAW_IGRAM) |
X |
|
|
| DIA |
Universal command for diagnostics |
|
|
|
X |
|
|
| DIAG_CONNECTOR |
Set Diag Connector Test |
0 |
0 |
|
X |
|
Enabled |
| 0x000000001 (Test: Single Pulse) |
X |
| 0x000000010 (Pin: Err) |
X |
| 0x000000020 (Pin: Fwd) |
X |
| 0x000000040 (Pin: AcqEn) |
X |
| 0x000000080 (Pin: TkDa) |
X |
| 0x000100000 (Condition: On Static Error) |
X |
| 0x000200000 (Condition: On Static Warning) |
X |
| 0x000400000 (Condition: On Measurement Abort) |
X |
|
|
| DIS |
Display LED |
LED Off |
0 |
|
X |
|
Enabled |
| 0 (LED Off) |
X |
| 1 (LED Red) |
X |
| 2 (LED Green) |
X |
| 3 (LED Yellow) |
X |
| 1000 (Restore LED Status) |
X |
|
|
| Prohibit Setting TCP/IP Parameters Via HTTP Server |
0 |
0 |
|
X |
|
|
| DLY |
Stabilisation Delay |
0 |
0 |
|
X |
|
|
| DTC |
Detector |
RT-DLATGS [Internal Pos.1] |
65120 |
Ready |
X |
|
Enabled |
Call |
| 65088 ([External Pos.1]) |
|
|
Enabled |
Connected |
| G_MOT=0xFE40, 1 |
|
| ENTRY_NUM_ADDR=0xFE40 |
|
|
| 65089 ([External Pos.2]) |
|
|
Enabled |
Connected |
| G_MOT=0xFE41, 1 |
|
| ENTRY_NUM_ADDR=0xFE41 |
|
|
| 65120 (RT-DLATGS [Internal Pos.1]) |
X |
|
Enabled |
Connected |
| G_MOT=0xFE60, 1 |
X |
X |
| ENTRY_NUM_ADDR=0xFE60 |
X |
X |
|
| 65121 ([Internal Pos.2]) |
|
|
Enabled |
Connected |
| G_MOT=0xFE61, 1 |
|
| ENTRY_NUM_ADDR=0xFE61 |
|
|
|
|
| DT_MOT |
Dummy command to enable/disable commands units of given type |
|
|
|
|
|
|
| D_MINMAX |
Dummy command to assign unit min and max values to the command where this unit is included |
|
|
|
|
|
|
| D_MOT |
Unit ID |
0 |
0, 0 |
|
|
|
|
| ENTRY_NUM_ADDR |
Unit address used to find according entry number of a combobox command |
0 |
0 |
|
|
|
|
| ENTRY_NUM_ADDR_SAVING |
Unit address used to find according entry number of a combobox command (on low option) |
0 |
0 |
|
|
|
|
| FCM |
Fast Communication Mode Timeout, ms |
0 |
0 |
|
X |
|
|
| FSS |
Full scan range |
0 |
0 |
|
X |
|
|
| GCV |
Get Command Value |
|
|
|
X |
|
|
| GET_MOT_POS |
Get Motor Position |
0 |
0 |
|
X |
|
|
| GET_POS |
Get Unit Position |
0 |
0 |
|
X |
|
|
| GTP |
Get Sample Temperature |
|
0 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=TemperatureController |
|
|
|
|
| GT_MOT |
Set motor to absolute position |
|
, 0 |
|
X |
|
|
| GUR |
Get Motor Resolution |
0 |
0, 0 |
|
X |
|
|
| G_MOT |
Set motor to absolute position |
65024 |
65024, 1 |
Ready |
X |
|
|
| G_MOT_FLOAT |
Set motor to absolute position using external integer parameter |
0 |
0, 0.000000, 0.000000 |
|
X |
|
|
| G_MOT_INT |
Set motor to absolute position using external integer parameter |
0 |
0, 0, 0 |
|
X |
|
|
| G_MOT_RANGE |
Set motor to absolute position; disable command if unit position is out of vaid range |
0 |
0, 0 |
|
X |
|
|
| HFW |
Wanted high frequency limit |
8000.000000 |
8000.000000 |
|
X |
|
|
| HMR |
Instrument humidity range |
0.000000 |
0.000000 |
|
X |
|
|
| HMT |
Instrument humidity target |
0.000000 |
0.000000 |
|
X |
|
|
| HPF |
High Pass Filter |
On |
1 |
|
X |
|
Enabled |
| 0 (Off) |
X |
| 1 (On) |
X |
|
|
| ITC |
Instrument test class |
0 |
0 |
Ready |
X |
|
|
| ITI |
Instrument test interval |
0 |
0 |
|
X |
|
|
| ITO |
OPUS inactivity timeout interval, s |
20 |
20 |
|
X |
|
|
| LFT |
Lifetime interval |
0 |
0 |
|
X |
|
|
| LFW |
Wanted low frequency limit |
0.000000 |
0.000000 |
|
X |
|
|
| LGL |
Log Level Bitmask |
Standard |
1 |
|
X |
|
Enabled |
| 1 (Standard) |
X |
| 2 (Verbose) |
X |
| 0x00F0 (Data Acquisition) |
X |
| 0x0F00 (CAN) |
X |
|
|
| LSR |
Switch laser on/off |
1 |
1 |
|
X |
|
|
| LWN |
Laser wave number |
0.000000 |
0.000000 |
|
X |
|
|
| MIN |
Scan Time in Minutes |
0.000000 |
0.000000 |
|
X |
|
|
| MOH |
Set motor to hold position |
0 |
0, 0 |
|
X |
|
|
| MOR |
Set motor to relative position |
0 |
0, 0 |
|
X |
|
|
| MOR_INT |
Set motor to relative position using external integer parameter |
0 |
0, 0 |
|
X |
|
|
| MOS |
Set motor to home position |
0 |
0, 0 |
|
X |
|
|
| MOT |
Set motor to absolute position |
0 |
0, 0 |
|
X |
|
|
| MOT_INT |
Set motor to absolute position using external integer parameter |
0 |
0, 0 |
|
X |
|
|
| MOT_STAT |
Wait for device status update |
0 |
0 |
|
X |
|
|
| MSR |
Motor status register |
0 |
0, 0 |
|
X |
|
|
| NSS |
Number of sample scans |
4 |
4 |
|
X |
|
|
| OPF |
Optical Filter Wheel |
Open |
0 |
Ready |
X |
|
Enabled |
Call |
| 0 (Open) |
X |
|
Enabled |
Connected |
| G_MOT=0xFF00, 0 |
X |
X |
|
| 1 (Filter Polystyrene) |
X |
|
Enabled |
Connected |
| G_MOT=0xFF00, 1 |
X |
X |
|
| 2 (Poly50) |
X |
|
Enabled |
Connected |
| G_MOT=0xFF00, 2 |
X |
X |
|
|
|
| OVS |
Overscan range |
2000 |
2000 |
Ready |
X |
|
|
| PBF |
Set Pass Band Factor |
0.430000 |
0.430000 |
|
X |
|
|
| PGN |
Preamplifier gain |
Standard |
1 |
|
X |
|
|
| RBT |
Read Digital Input |
|
0, 0 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=AdiDigitalIn |
|
|
|
|
| RDR |
Sampling Data Rate |
*?RDS=4096?* |
21600 |
|
X |
|
Enabled |
| 21600 (*?RDS=4096?*) |
X |
|
|
| RDX |
Instrument ready mask |
Source |
32 |
|
X |
|
Enabled |
| 2 (Detector) |
X |
| 8 (Sample Temperature) |
X |
| 32 (Source) |
X |
| 34 (OVP) |
X |
|
|
| RDY |
Instrument ready status |
0 |
0 |
|
X |
|
|
| REP |
Repeat measurement count |
0 |
0 |
|
X |
|
|
| REP_CMD |
Send command with current value |
|
|
|
X |
|
|
| RES |
Resolution |
14.220000 |
14.220000 |
|
X |
|
|
| RSN |
Running sample number |
0 |
0 |
|
X |
|
|
| SBT |
Set Digital Output |
|
0, 0, 0 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=AdiDigitalOut |
|
|
|
|
| SBY |
Probe Trigger on/off |
Standby Off |
0 |
|
X |
|
Enabled |
| 0 (Standby Off) |
X |
| 1 (Standby On) |
X |
| 2 (Standby On OPUS Timeout) |
|
|
|
| SET_CAN_RECEIVE_BUFFER_SIZE_MESSAGES |
Set CAN receive buffer size, messages |
512 |
512 |
|
X |
|
|
| SET_DACQ_MEM_POOL_SIZE_BUFFERS |
Set data acquisition memory pool size, buffers |
6 |
6 |
|
X |
|
|
| SET_DACQ_MEM_POOL_SIZE_BYTES |
Set data acquisition memory pool size, bytes |
4194304 |
4194304 |
|
X |
|
|
| SET_HTTP_SERVER_TX_POOL_SIZE_BUFFERS |
Set data http server tx memory pool size, buffers |
4 |
4 |
|
X |
|
|
| SET_OUTPUT |
Set Output of Temperature Controller, percentage of maximal power |
0.000000 |
0.000000 |
|
X |
|
|
| SET_SCR_REINIT_ON |
|
1 |
1 |
|
X |
|
|
| SET_TEST_DOWNLOAD_FILE_SIZE_BYTES |
Set test download file size, bytes |
524288 |
524288 |
|
X |
|
|
| SFM |
Sample Form |
|
|
|
X |
|
|
| SNM |
Sample Name |
|
|
|
X |
|
|
| SON |
Probe Trigger on/off |
Off |
0 |
|
X |
|
Enabled |
| 0 (Off) |
X |
| 1 (Internal Trigger) |
X |
| 2 (External Trigger) |
X |
| 3 (Both Trigger) |
X |
|
|
| SOT |
Probe Trigger on/off |
Scans |
0 |
|
X |
|
Enabled |
Call |
| 0 (Scans) |
X |
|
| 1 (Minutes) |
X |
|
| 2 (Rotations) |
|
|
Enabled |
Connected |
| DT_MOT=Rotator |
|
|
|
|
| SRC |
Source |
MIR |
101 |
Ready |
X |
|
Enabled |
Call |
| 0 (Off) |
X |
|
Enabled |
Connected |
| G_MOT=0xFE00, 0 |
X |
X |
|
| 101 (MIR) |
X |
|
Enabled |
Connected |
| G_MOT=0xFE00, 1 |
X |
X |
| ENTRY_NUM_ADDR=0xFE00 |
X |
X |
|
|
|
| SST |
Set Sample Temperature |
0.000000 |
0.000000 |
|
|
|
Enabled |
Call |
| 0 |
|
|
Enabled |
Connected |
| DT_MOT=TemperatureController |
|
| D_MINMAX=TemperatureController |
|
|
|
|
| STS |
Set Instrument Test Status |
Disable |
0 |
|
X |
|
Enabled |
Call |
| 0 (Disable) |
X |
|
| 1 (Reinitialize) |
X |
|
| 2 (Set To Failed) |
X |
|
| 5 (Increase Interval) |
X |
|
| 6 (Remove) |
X |
|
| 7 (Set To Expired) |
X |
|
|
|
| TEST_OUTP_STEP |
Test Command |
0 |
0 |
|
X |
|
|
| TMR |
Instrument temperature range |
0.000000 |
0.000000 |
|
X |
|
|
| TMT |
Instrument temperature target |
-300.000000 |
-300.000000 |
|
X |
|
|
| TRQ |
Turn frequency |
0 |
0 |
|
X |
|
|
| TRW |
Input signal selection |
IR |
0 |
|
X |
|
Enabled |
| 0 (IR) |
X |
| 1 (Test ramp) |
X |
| 2 (Shorted input) |
X |
| 3 (Laser) |
X |
|
|
| TSR |
Tolerance scan range |
2000 |
2000 |
|
X |
|
|
| UWN |
ITC / channel specific LWN On/Off |
On |
1 |
|
X |
|
Enabled |
| 0 (Off) |
X |
| 1 (On) |
X |
|
|
| VEL |
Velocity |
7.500000 |
7.500000 |
|
X |
|
|
| VSN |
Firmware version |
|
|
|
X |
|
|
| WAIT_FOR_UNIT_READY |
Wait for unit ready |
0 |
0, 0 |
|
X |
|
|
| WAIT_MS |
Wait for delay, ms |
0.000000 |
0.000000 |
|
X |
|
|
| WRK |
Set type of command execution |
0 |
0 |
|
X |
|
|
| XND |
Additional delay of the IR signal relative to the laser one [ns] |
0.000000 |
0.000000 |
|
X |
|
|
| XWN |
Instrument test class specific laser wave number |
|
|
|
X |
|
|
| _GR |
Get measurement result |
0 |
0 |
|
X |
|
F |
| _ME |
Measure |
0 |
0 |
|
X |
|
F |
| _SP |
Set measurement parameters |
0 |
0 |
|
X |
|
|